MyLRC +
Administrative Rules

CHAPTER 20:01:08

INSTALLATION REQUIREMENTS FOR SELF-CONTAINED ELECTRONIC AND MECHANICAL PITLESS SCALES

Section

20:01:08:01                               Foundation and support.

20:01:08:02                               Piers.

20:01:08:02.01                          Floating slab.

20:01:08:03                               Clearance.

20:01:08:04                               Drainage.

20:01:08:05                               Access for service.

20:01:08:06                               Other specifications to be followed.

20:01:08:07                               Exemptions.

20:01:08:08                               Livestock scale installation.

20:01:08:09                               Repealed

20:01:08:10                               Repealed.




Rule 20:01:08:01 Foundation and support.

          20:01:08:01.  Foundation and support. The area of the foundation and support-bearing piers shall be matched to existing soil-bearing capabilities. Soil stabilized at the desired grade shall support at least 3,000 pounds per square foot at pier locations. The owner is responsible for design modification to suit the existing soil conditions.

          Source: 8 SDR 44, effective October 27, 1981; 12 SDR 151, 12 SDR 155, effective July 1, 1986.

          General Authority:SDCL 37-22-3.

          Law Implemented:SDCL 37-22-3.




Rule 20:01:08:02 Piers.

          20:01:08:02.  Piers. Piers shall be of reinforced concrete poured to the depth of the frost line but not less than four feet. The location and size of the piers shall meet the manufacturer's design. All piers shall be connected by a reinforced solid concrete slab at least four inches thick. Piers shall support the combined loads of the weight of the scale, the weighbridge, and the maximum anticipated load of the scale. They shall distribute these loads evenly over the underlying ground so there is minimum settlement of the structure throughout. Anchor bolts shall be embedded in piers according to the manufacturer's design.

          Source: 8 SDR 44, effective October 27, 1981; 12 SDR 151, 12 SDR 155, effective July 1, 1986; 24 SDR 98, effective January 29, 1998.

          General Authority:SDCL 37-22-3.

          Law Implemented:SDCL 37-22-1, 37-22-3.




Rule 20:01:08:02.01 Floating slab.

          20:01:08:02.01.  Floating slab. In lieu of the pier structure required by § 20:01:08:02, a floating slab of concrete, a minimum of 12 inches thick and reinforced with two rows of five-eighths inch rebar on one-foot centers, may be installed. The owner is responsible for design modification to suit existing soil conditions.

          Source: 11 SDR 50, effective October 14, 1984; 12 SDR 151, 12 SDR 155, effective July 1, 1986; 24 SDR 98, effective January 29, 1998.

          General Authority:SDCL 37-22-3.

          Law Implemented:SDCL 37-22-1, 37-22-3.




Rule 20:01:08:03 Clearance.

          20:01:08:03.  Clearance. Accumulations of wind-blown debris, dirt, manure, ice, snow, and water may not impede any of the live elements of the scale, including weighbridge assembly.

          Source: 8 SDR 44, effective October 27, 1981; 11 SDR 50, effective October 14, 1984; 12 SDR 151, 12 SDR 155, effective July 1, 1986.

          General Authority:SDCL 37-22-3.

          Law Implemented:SDCL 37-22-3.




Rule 20:01:08:04 Drainage.

          20:01:08:04.  Drainage. Grading around the perimeter of the scale shall divert surface water away from the scale.

          Source: 8 SDR 44, effective October 27, 1981; 12 SDR 151, 12 SDR 155, effective July 1, 1986.

          General Authority:SDCL 37-22-3.

          Law Implemented:SDCL 37-22-3.




Rule 20:01:08:05 Access for service.

          20:01:08:05.  Access for service. The scale mechanism shall be accessible for inspection and servicing.

          Source: 8 SDR 44, effective October 27, 1981; 12 SDR 151, 12 SDR 155, effective July 1, 1986.

          General Authority: SDCL 37-22-3.

          Law Implemented: SDCL 37-22-3.




    20:01:08:06.  Other specifications to be followed. NIST Handbook 44, 2020, must be followed for specifications and design requirements not provided in this chapter.

    Source: 8 SDR 44, effective October 27, 1981; 11 SDR 50, effective October 14, 1984; 12 SDR 151, 12 SDR 155, effective July 1, 1986; 16 SDR 84, effective November 9, 1989; 18 SDR 198, effective June 4, 1992; 26 SDR 33, effective September 16, 1999; 43 SDR 56, effective October 17, 2016; 48 SDR 18, effective August 30, 2021.

    General Authority: SDCL 37-22-3.

    Law Implemented: SDCL 37-22-3.

    Reference: NIST Handbook 44, 2020, National Institute of Standards and Technology, issued October 2019. Copies may be viewed or downloaded at no cost on the National Institute of Science and Technology website located at: https://www.nist.gov/pml/weights-and-measures/publications/nist-handbooks/other-nist-handbooks/other-nist-handbooks-2-2.




Rule 20:01:08:07 Exemptions.

          20:01:08:07.  Exemptions. The rules of this chapter do not apply to portable scales for construction materials, provided they are not installed for more than six months.

          Source: 8 SDR 44, effective October 27, 1981; 12 SDR 151, 12 SDR 155, effective July 1, 1986; 16 SDR 84, effective November 9, 1989.

          General Authority:SDCL 37-22-3.

          Law Implemented:SDCL 37-22-3.




Rule 20:01:08:08 Livestock scale installation.

          20:01:08:08.  Livestock scale installation. In addition to meeting all of the other requirements of this chapter, fully electronic and mechanical pitless livestock scales must be permanently installed with a crawl space between the weighbridge steel and the concrete slab of sufficient size to allow for cleaning and repairs. All weighing and load receiving elements should be fully housed to protect them from environmental factors.

          Source: 11 SDR 50, effective October 14, 1984; 12 SDR 151, 12 SDR 155, effective July 1, 1986; 24 SDR 98, effective January 29, 1998.

          General Authority:SDCL 37-22-3.

          Law Implemented:SDCL 37-22-1, 37-22-3.




Rule 20:01:08:09 Repealed.

          20:01:08:09.  Livestock scale certification process.Repealed.

          Source: 11 SDR 50, effective October 14, 1984; 12 SDR 151, 12 SDR 155, effective July 1, 1986; 16 SDR 84, effective November 9, 1989; 18 SDR 198, effective June 4, 1992; repealed, 24 SDR 98, effective January 29, 1998.




Rule 20:01:08:10 Repealed.

          20:01:08:10.  Livestock scale owner requirements.Repealed.

          Source: 11 SDR 50, effective October 14, 1984; 12 SDR 151, 12 SDR 155, effective July 1, 1986; 18 SDR 198, effective June 4, 1992; repealed, 24 SDR 98, effective January 29, 1998.

Online Archived History: