<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>span { white-space: pre-wrap; } p.sce49ff27-aa9a-43aa-a3df-425784232206P0 { margin-top: 0; margin-bottom: 0; margin-left: 0; margin-right: 0; text-indent: 0.00in; text-align: justify; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; line-height: 108%; } span.sce49ff27-aa9a-43aa-a3df-425784232206C0 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sce49ff27-aa9a-43aa-a3df-425784232206C0-000000 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.sce49ff27-aa9a-43aa-a3df-425784232206C0-000001 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.sce49ff27-aa9a-43aa-a3df-425784232206C0-000002 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sce49ff27-aa9a-43aa-a3df-425784232206000003 { color: black; background: white; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    </span><a href="https://sdlegislature.gov/Rules?Rule=61:08:09:02"><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000000">61:08:09:02</span></a><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000001">.  Schedule of inspections.</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0"> An inspector shall conduct an initial inspection of each historic boiler during the first year following March 10, 1997. The </span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">inspector's </span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">initial inspection shall include an ultrasonic examination conducted pursuant to Article 4, </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">s</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">ection V, </span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">ASME Boiler </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">and</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0"> Pressure Vessel Code</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">, </span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">July 1, 2021; </span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">an internal inspection conducted pursuant to § </span><a href="https://sdlegislature.gov/Rules?Rule=61:08:09:05"><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000002">61:08:09:05</span></a><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">;</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0"> and an external inspection pursuant to § </span><a href="https://sdlegislature.gov/Rules?Rule=61:08:09:31"><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000002">61:08:09:31</span></a><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206000003"> </span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    During the second year following March 10, 1997, an inspector shall conduct a hydrostatic test pursuant to § </span><a href="https://sdlegislature.gov/Rules?Rule=61:08:09:24"><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000002">61:08:09:24</span></a><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206000003"> </span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    During the third year following March 10, 1997, and every sixth year thereafter, an inspector shall conduct a hydrostatic test or an external inspection.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206000003"> </span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    During the sixth year following March 10, 1997, and every sixth year thereafter, an inspector shall conduct an ultrasonic examination or an internal inspection.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206000003"> </span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    Additional tests may be performed at any time an inspector considers it necessary for continued safe operation of the boiler.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206000003"> </span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000001">Source:</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0"> 23 SDR 139, effective March 5, 1997; 30 SDR 48, effective October 16, 2003</span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">; 50 SDR 47, effective October 16, 2023</span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000001">General Authority:</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-29A-14.1"><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000002">34-29A-14.1</span></a><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000001">Law Implemented:</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-29A-14.1"><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000002">34-29A-14.1</span></a><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206000003"> </span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">    </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000001">Reference:</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0"> </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000001">ASME Boiler &amp; Pressure Vessel Code</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0-000001">, </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">July 1, 2021, edition, section V</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">. Copies may be obtained from the American Society of Mechanical Engineers, </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">Two Park Avenue, New York, NY 10016</span><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206C0">. </span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">Section V, $583</span><span class="sce49ff27-aa9a-43aa-a3df-425784232206C0">.</span></p><p dir="ltr" class="sce49ff27-aa9a-43aa-a3df-425784232206P0"><span xml:space="preserve" class="sce49ff27-aa9a-43aa-a3df-425784232206000003"> </span></p></div></body></html>