<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>span { white-space: pre-wrap; } p.s847c6488-033c-44e2-8612-8b785b7b4a1cP0 { margin-top: 0; margin-bottom: 0; margin-left: 0; margin-right: 0; text-indent: 0.00in; text-align: justify; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; line-height: 108%; } span.s847c6488-033c-44e2-8612-8b785b7b4a1cC0 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000000 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s847c6488-033c-44e2-8612-8b785b7b4a1c000002 { color: black; background: white; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000003 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">    </span><a href="https://sdlegislature.gov/Rules?Rule=61:08:09:39"><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000000">61:08:09:39</span></a><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">.  Repairs to historic power boilers.</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0"> </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">E</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">ach welded repair must conform insofar as possible to Part </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">3</span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">, 20</span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">2</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">1 </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">National Board Inspection Code</span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">. The repair standard selected must be the one most compatible with the nature of the repair, the original construction, and the present operating conditions.</span></p><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1c000002"> </span></p><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">    </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">Source:</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0"> 23 SDR 139, effective March 5, 1997; 30 SDR 48, effective October 16, 2003</span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">; 50 SDR 47, effective October 16, 2023</span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">.</span></p><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">    </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">General Authority:</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-29A-14.1"><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000003">34-29A-14.1</span></a><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">.</span></p><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">    </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">Law Implemented:</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-29A-14.1"><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000003">34-29A-14.1</span></a><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">.</span></p><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1c000002"> </span></p><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">    </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">Reference:</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0"> </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">National Board Inspection Code</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0-000001">, </span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">July 1, 2021, edition</span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">. Copies may be obtained from the National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229-1183. Cost is $</span><span class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0">325</span><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1cC0"> plus shipping and handling charges.</span></p><p dir="ltr" class="s847c6488-033c-44e2-8612-8b785b7b4a1cP0"><span xml:space="preserve" class="s847c6488-033c-44e2-8612-8b785b7b4a1c000002"> </span></p></div></body></html>