<html xmlns:v="urn:schemas-microsoft-com:vml" xmlns:o="urn:schemas-microsoft-com:office:office" xmlns:w="urn:schemas-microsoft-com:office:word" xmlns="http://www.w3.org/TR/REC-html40"> <head> <title>Rule 12:56:17:02 Operational area containment requirements.</title> <META NAME="Keywords" Content="Administrative Rules 12:56:17:02"> <META NAME="Description" Content="Administrative Rules 12:56:17:02 Operational area containment requirements."> <meta http-equiv=Content-Type content="text/html; charset=windows-1252"> <meta name=ProgId content=Word.Document> <meta name=Generator content="Microsoft Word 10"> <meta name=Originator content="Microsoft Word 10"> <link rel=File-List href="1256170000200D_files/filelist.xml"> <!--[if gte mso 9]><xml> <o:DocumentProperties> <o:Author>lrpr14533</o:Author> <o:LastAuthor>lrpr14296</o:LastAuthor> <o:Revision>2</o:Revision> <o:TotalTime>0</o:TotalTime> <o:Created>2011-09-20T14:01:00Z</o:Created> <o:LastSaved>2011-09-20T14:01:00Z</o:LastSaved> <o:Pages>2</o:Pages> <o:Words>520</o:Words> <o:Characters>2964</o:Characters> <o:Company>State of South Dakota</o:Company> <o:Lines>24</o:Lines> <o:Paragraphs>6</o:Paragraphs> <o:CharactersWithSpaces>3478</o:CharactersWithSpaces> <o:Version>10.6870</o:Version> </o:DocumentProperties> </xml><![endif]--><!--[if gte mso 9]><xml> <w:WordDocument> <w:PunctuationKerning/> <w:Compatibility> <w:BreakWrappedTables/> <w:SnapToGridInCell/> <w:WrapTextWithPunct/> <w:UseAsianBreakRules/> </w:Compatibility> <w:BrowserLevel>MicrosoftInternetExplorer4</w:BrowserLevel> </w:WordDocument> </xml><![endif]--> <style> <!-- /* Font Definitions */ @font-face {font-family:Calibri; panose-1:2 15 5 2 2 2 4 3 2 4; mso-font-charset:0; mso-generic-font-family:swiss; mso-font-pitch:variable; mso-font-signature:-1610611985 1073750139 0 0 159 0;} @font-face {font-family:Times; panose-1:2 2 6 3 5 4 5 2 3 4; mso-font-charset:0; mso-generic-font-family:roman; mso-font-pitch:variable; mso-font-signature:536902279 -2147483648 8 0 511 0;} /* Style Definitions */ p.MsoNormal, li.MsoNormal, div.MsoNormal {mso-style-parent:""; margin:0in; margin-bottom:.0001pt; mso-pagination:widow-orphan; mso-layout-grid-align:none; punctuation-wrap:simple; text-autospace:none; font-size:10.0pt; font-family:Times; mso-fareast-font-family:"Times New Roman"; mso-bidi-font-family:"Times New Roman";} @page Section1 {size:8.5in 11.0in; margin:1.0in 1.0in 1.0in 1.0in; mso-header-margin:.5in; mso-footer-margin:.5in; mso-paper-source:0;} div.Section1 {page:Section1;} --> </style> <!--[if gte mso 10]> <style> /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:Calibri;} </style> <![endif]--><!--[if gte mso 9]><xml> <o:shapedefaults v:ext="edit" spidmax="2050"/> </xml><![endif]--><!--[if gte mso 9]><xml> <o:shapelayout v:ext="edit"> <o:idmap v:ext="edit" data="1"/> </o:shapelayout></xml><![endif]--> </head> <body lang=EN-US style='tab-interval:.5in'> <div class=Section1> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>12:56:17:02.&nbsp;&nbsp;</b></span><b style='mso-bidi-font-weight:normal'><span style='font-size:12.0pt;mso-bidi-font-size: 10.0pt'>O</span></b><b style='mso-bidi-font-weight:normal'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'>perational area containment requirements.</span></b><span style='font-size:12.0pt; mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'> After February 1, 1995, the following requirements for containment apply to those operational areas where operational area containment is required pursuant to &#167;&nbsp;12:56:17:01:<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(1)&nbsp;&nbsp;Operational area activities must be carried out in a manner that prevents escape of discharges that may result in unreasonable adverse effects on the environment;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(2)&nbsp;&nbsp;Operational area activities must be carried out on an impervious surface that is designed to catch and contain any discharges in the operational area;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(3)&nbsp;&nbsp;The operational area containment must be constructed in accordance with professional engineering practices which include the following:<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(a)&nbsp;&nbsp;The material used must be of sufficient thickness and strength to withstand the weight and movement of any equipment that may be placed or parked within the operational area containment;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(b)&nbsp;&nbsp;All seams and cracks must be sealed;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(c)&nbsp;&nbsp;The operational area containment must be constructed of concrete or other materials approved by the secretary prior to construction or installation. If materials other than concrete are used, information must be provided by the applicant to the secretary which includes chemical compatibility, permeability, and physical characteristics of materials proposed to assure operational area containment integrity under conditions of proposed use. A written confirmation of compatibility of synthetic materials must be kept at the operational area or at the nearest local office of the operator;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(d)&nbsp;&nbsp;For liquid pesticides, including container and equipment rinsates, the operational area containment must be curbed or sloped to contain discharges so as to facilitate recovery of discharged materials and to prevent liquids from adjacent surfaces from flowing onto the operational area containment. To prevent unreasonable adverse effects on the environment as defined in SDCL chapter <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=38-21">38-21</A>, the operational area containment must be of sufficient capacity and surface area to contain discharges from the single largest container or application system operated or cleaned within the operational area and to prevent spillage onto unprotected areas;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(e)&nbsp;&nbsp;For nonliquid pesticides, the operational area containment must extend beneath any conveyors or augers used in operational area activities unless the conveyors or augers are fully enclosed and constructed to prevent discharge. To prevent unreasonable adverse effects on the environment as defined in SDCL chapter <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=38-21">38-21</A>, the operational area containment must be of adequate surface area to contain discharges from the largest container or equipment operated within the operational area containment. The operational area containment must be constructed to prevent liquids from adjacent surfaces from flowing onto the operational area containment;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(4)&nbsp;&nbsp;Discharges and other accumulated materials must be promptly recovered from the operational area containment. Accumulated liquids or materials containing pesticides must be disposed of in accordance with chapter 12:56:02. Accumulations of precipitation may be discharged from the operational area containment as surface runoff if the operational area containment was cleaned after the last use.<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>Source:</b> 18 SDR 49, effective September 15, 1991; 20 SDR 91, effective December 19, 1993; 38 SDR 40, effective September 20, 2011.<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>General Authority:</b> SDCL <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=38-21-15">38-21-15</A>, <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=38-21-15.1">38-21-15.1</A>, <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=38-21-51">38-21-51.</A><o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>Law Implemented:</b> SDCL <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=38-21-15">38-21-15</A>, <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=38-21-15.1">38-21-15.1.</A><o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> </div> </body> </html>