<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>span { white-space: pre-wrap; } p.s4b66a59d-904d-4d6c-a108-28e46bd10486Normal { text-align: justify; font-family: 'Times New Roman', 'serif'; font-size: 12pt; line-height: 108%; margin-top: 0; margin-left: 0; margin-right: 0; margin-bottom: .001pt; } span.s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont { font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000000 { color: #0000FF; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000001 { font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s4b66a59d-904d-4d6c-a108-28e46bd10486000002 { font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000003 { color: #0000FF; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s4b66a59d-904d-4d6c-a108-28e46bd10486Hyperlink { color: #0000FF; font-family: 'Times New Roman', 'serif'; font-size: 12pt; text-decoration: underline; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    </span><a href="https://sdlegislature.gov/Rules?Rule=24:06:07:04"><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000000">24:06:07:04</span></a><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000001">.  Heating and air conditioning systems. </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">A school bus must contain a heating system</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> installed in accordance with the section entitled "Heating and Air Conditioning Systems" on pages </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">53</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> to </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">57, inclusive,</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> of the National School Transportation Specifications &amp; Procedures,</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> May</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> 20</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">25</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> Revised Edition.</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> If an air conditioning system is installed on a school bus, it must be installed in accordance with these standards.</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    </span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">In addition, the following standards apply to </span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">each </span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">school </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">bus type</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">:</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    (1)  The minimum installation for a Type A bus</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">, as defined on page 407 of the National School Transportation Specifications &amp; Procedures, May 2025 Revised Edition (NSTSP),</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> is one front fresh air heater, utilizing the manufacturer's standard heater with a defroster core and a driver's deflector, and one or more rear recirculating underseat heaters with a minimum of 38,000 BTUs;</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    (2)  The minimum installation for </span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">a </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">Type B or C bus</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">, as defined on page 407 of the NSTSP,</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> is one left front fresh air heater with a defroster core and a driver's deflector with a minimum of 80,000 BTUs, one right cowl recirculating heater with a minimum of 50,000 BTUs</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">; and</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">        (a)  If the bus has a capacity of less than fifty-nine passengers, a rear underseat recirculating heater with a minimum of 75,000 BTUs; or</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">        (b)  If the bus has a capacity of fifty-nine or more passengers, two rear underseat recirculating heaters, or a combination of one midship heater and one rear recirculating heater. Each heater must have a minimum of 75,000 BTUs; and</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    (3)  </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">The minimum installation for a type D bus</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">, as defined on page 408 of the NSTSP,</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> is one front fresh air heater with a defroster core and </span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">a </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">minimum of 80,000 BTUs, a driver</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">'</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">s underseat heater with a minimum of 14,000 BTUs; and</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">        (a)  </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">If the bus has a capacity of less than fifty-nine passengers, a rear underseat recirculating heater with a minimum of 75,000 BTUs; or</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">        (b)  </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">If the bus has a capacity of fifty-nine or more passengers, two rear underseat recirculating heaters, or a combination of one midship heater and one rear recirculating heater. Each heater must have a minimum of 75,000 BTUs</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">.</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000001">Source:</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> 22 SDR 61, effective November 9, 1995; 30 SDR 181, effective May 20, 2004; 33 SDR 152, effective April 5, 2007; 38 SDR 58, effective October 17, 2011; 44 SDR 43, effective September 13, 2017</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">; 53 SDR 22, effective September 8, 2026</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">.</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000001">General Authority:</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=13-29-6"><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000003">13-29-6</span></a><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">.</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000001">Law Implemented:</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=13-29-6"><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000003">13-29-6</span></a><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">.</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">    </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000001">Reference:</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> "School Bus Types," on page</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">s</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">407 to 408,</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> and "Heating and Air Conditioning Systems," pages </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">53</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> to </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">57</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">, </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont-000001">National School Transportation Specifications &amp; Procedures</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">, </span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">May 2025</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont"> Revised Edition</span><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">, National Conference of School Transportation</span><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">. Copies may be obtained from </span><a href="http://www.ncstonline.org/"><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486Hyperlink">www.ncstonline.org</span></a><span class="s4b66a59d-904d-4d6c-a108-28e46bd10486DefaultParagraphFont">.</span></p><p dir="ltr" class="s4b66a59d-904d-4d6c-a108-28e46bd10486Normal"><span xml:space="preserve" class="s4b66a59d-904d-4d6c-a108-28e46bd10486000002"> </span></p></div></body></html>