<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>span { white-space: pre-wrap; } p.s65347e00-bc2f-44be-ba4a-b76779167cc7P0 { margin-top: 0; margin-bottom: 0; margin-left: 0; margin-right: 0; text-indent: 0.00in; text-align: justify; background: white; font-family: Times; font-size: 12pt; line-height: 108%; } span.s65347e00-bc2f-44be-ba4a-b76779167cc7C0 { background: white; font-family: Times; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000000 { color: #0000FF; background: white; font-family: Times; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000001 { background: white; font-family: Times; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s65347e00-bc2f-44be-ba4a-b76779167cc7000002 { background: white; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000003 { background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000004 { color: #0000FF; background: white; font-family: Times; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:06.01"><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000000">74:36:07:06.01</span></a><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000001">.  Standards of performance for hospital/medical/infectious waste incinerators constructed on or before June 20, 1996.</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> </span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">Title </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">40</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">,</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> C.F.R. Part 60, Subpart Ce (July 1, 20</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">24</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">), is incorporated into this rule by reference. Designated facilities</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">, as described in</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> Subpart Ce</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">,</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">must</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> comply with the requirements for state plan approval in 40 C.F.R. §§ 60.32e </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">through</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> 60.38e (July 1, 20</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">24</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">).</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    The owner or operator of a hospital/medical/infectious waste incinerator constructed on or before June 20, 1996, that decides to cease operation </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">must</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> notify the department</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">,</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> within six months of </span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">the </span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">EPA's approval of the state plan for hospital/medical/infectious waste incinerators. The written notification </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">must</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> inform the department of when the unit will be shut</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">down. The shut</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> </span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">down date may not exceed one year after </span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">the </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">EPA's approval of the state plan for hospital/medical/infectious waste incinerators.</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    The owner or operator of a hospital/medical/infectious waste incinerator constructed on or before June 20, 1996, </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">which</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> decides to comply with the requirements of this section </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">must</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> submit a compliance plan within six months of state plan approval that meets the following deadlines:</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    (1)  Submit a Part 70 operating permit application and design drawings of the air pollution control device to the department within one year of state plan approval;</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    (2)  Submit a copy of the purchase order or other documentation indicating an order has been placed for the major components of the air pollution control device within </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">fifteen</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> months of state plan approval;</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    (3)  Begin initiation of site preparation for installation of the air pollution control device within </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">two</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> years after state plan approval;</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    (4)  Complete installation of the air pollution control device within </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">thirty</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> months after state plan approval; and</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    (5)  Conduct a performance test within </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">thirty-three</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> months after state plan approval.</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    The owner or operator </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">must</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> comply with 40 C.F.R. §§ 60.34e and 60.36e (July 1, 20</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">24</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">) within one year after state plan approval. The owner or operator </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">must</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> comply with the remaining requirements in this section within three years after state plan approval or by September 15, 2002, whichever is earlier.</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000001">Source:</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> 25 SDR 123, effective April 4, 1999; 26 SDR 168, effective June 27, 2000; 30 SDR 26, effective September 1, 2003; 31 SDR 101, effective January 2, 2005; 32 SDR 209, effective June 13, 2006; 33 SDR 217, effective June 13, 2007; 36 SDR 207, effective June 28, 2010; 39 SDR 219, effective June 25, 2013; 42 SDR 52, effective October 13, 2015</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000003">; 44 SDR 43, effective September 13, 2017; 46 SDR 64, effective November 25, 2019</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000003">; 52 SDR 27, effective September 17, 2025</span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">.</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000001">General Authority:</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-6"><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000004">34A-1-6</span></a><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">, </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-18"><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000004">34A-1-18</span></a><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">.</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">    </span><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000001">Law Implemented:</span><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-18"><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0-000004">34A-1-18</span></a><span class="s65347e00-bc2f-44be-ba4a-b76779167cc7C0">.</span></p><p dir="ltr" class="s65347e00-bc2f-44be-ba4a-b76779167cc7P0"><span xml:space="preserve" class="s65347e00-bc2f-44be-ba4a-b76779167cc7000002"> </span></p></div></body></html>