<html xmlns:v="urn:schemas-microsoft-com:vml" xmlns:o="urn:schemas-microsoft-com:office:office" xmlns:w="urn:schemas-microsoft-com:office:word" xmlns="http://www.w3.org/TR/REC-html40"> <head> <title>Rule 74:12:03:02 Secretary to approve method of plugging.</title> <META NAME="Keywords" Content="Administrative Rules 74:12:03:02"> <META NAME="Description" Content="Administrative Rules 74:12:03:02 Secretary to approve method of plugging."> <meta http-equiv=Content-Type content="text/html; charset=windows-1252"> <meta name=ProgId content=Word.Document> <meta name=Generator content="Microsoft Word 10"> <meta name=Originator content="Microsoft Word 10"> <link rel=File-List href="7412030000200d_files/filelist.xml"> <!--[if gte mso 9]><xml> <o:DocumentProperties> <o:Author>lrpr14533</o:Author> <o:LastAuthor>lrpr14296</o:LastAuthor> <o:Revision>2</o:Revision> <o:TotalTime>1</o:TotalTime> <o:Created>2012-01-12T20:38:00Z</o:Created> <o:LastSaved>2012-01-12T20:38:00Z</o:LastSaved> <o:Pages>2</o:Pages> <o:Words>545</o:Words> <o:Characters>3109</o:Characters> <o:Company>State of South Dakota</o:Company> <o:Lines>25</o:Lines> <o:Paragraphs>7</o:Paragraphs> <o:CharactersWithSpaces>3647</o:CharactersWithSpaces> <o:Version>10.6870</o:Version> </o:DocumentProperties> </xml><![endif]--><!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Print</w:View> <w:PunctuationKerning/> <w:Compatibility> <w:BreakWrappedTables/> <w:SnapToGridInCell/> <w:WrapTextWithPunct/> <w:UseAsianBreakRules/> </w:Compatibility> <w:BrowserLevel>MicrosoftInternetExplorer4</w:BrowserLevel> </w:WordDocument> </xml><![endif]--> <style> <!-- /* Font Definitions */ @font-face {font-family:Times; panose-1:2 2 6 3 5 4 5 2 3 4; mso-font-charset:0; mso-generic-font-family:roman; mso-font-pitch:variable; mso-font-signature:536902279 -2147483648 8 0 511 0;} @font-face {font-family:Calibri; mso-font-charset:0; mso-generic-font-family:swiss; mso-font-pitch:variable; mso-font-signature:-1610611985 1073750139 0 0 159 0;} /* Style Definitions */ p.MsoNormal, li.MsoNormal, div.MsoNormal {mso-style-parent:""; margin:0in; margin-bottom:.0001pt; mso-pagination:widow-orphan; mso-layout-grid-align:none; punctuation-wrap:simple; text-autospace:none; font-size:10.0pt; font-family:Times; mso-fareast-font-family:"Times New Roman"; mso-bidi-font-family:"Times New Roman";} @page Section1 {size:8.5in 11.0in; margin:1.0in 1.0in 1.0in 1.0in; mso-header-margin:.5in; mso-footer-margin:.5in; mso-paper-source:0;} div.Section1 {page:Section1;} --> </style> <!--[if gte mso 10]> <style> /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:Calibri;} </style> <![endif]--><!--[if gte mso 9]><xml> <o:shapedefaults v:ext="edit" spidmax="2050"/> </xml><![endif]--><!--[if gte mso 9]><xml> <o:shapelayout v:ext="edit"> <o:idmap v:ext="edit" data="1"/> </o:shapelayout></xml><![endif]--> </head> <body lang=EN-US style='tab-interval:.5in'> <div class=Section1> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>74:12:03:02.&nbsp;&nbsp;Secretary to approve method of plugging.</b> Before a well is abandoned, it must be plugged in a manner that will permanently confine all oil, gas, water, and other fluids to the strata in which they originally occurred. Plugging requirements may vary from area to area depending on geological characteristics. Variations in procedure may be used only after approval of the secretary. Plugging must conform to the following requirements:<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(1)&nbsp;&nbsp;The method of placing cement in the hole must be proposed by the operator and approved by the secretary;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(2)&nbsp;&nbsp;No substance other than that normally used in drilling or plugging operations may be placed in any well at any time before or during plugging operations;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(3)&nbsp;&nbsp;The interval between all cement plugs must be filled with a heavy mud-laden fluid approved by the secretary;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(4)&nbsp;&nbsp;Cement plugs must be placed in all oil, gas, and injection wells as follows:<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(a)&nbsp;&nbsp;Wells without production casing:<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:3'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(i)<span style='mso-tab-count: 2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>All aquifers, salt zones, and fluid-bearing formations must be sealed or separated with individual cement plugs, circulated to fill at least 100 feet of hole. Each individual cement plug must be at least 50 feet above the top of these formations, as specified by the secretary;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><span style='mso-tab-count: 1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt; font-family:"Times New Roman"'>(ii)<span style='mso-tab-count:1'> </span>Cement must be circulated to fill at least a 100-foot interval, of which at least 50 feet must be above the shoe of the surface casing; and<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:3'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(iii)<span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>A cement plug of 25 feet must be set at the surface;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(b)&nbsp;&nbsp;Wells with production casing:<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:3'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(i)<span style='mso-tab-count: 2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>All perforations must be isolated, either by squeeze cementing or placing a cast iron bridge plug, with a minimum of 20 feet of cement, above the perforations. A bridge plug may not be set in any well at a depth where the pressure or temperature exceeds the ratings recommended by the bridge plug manufacturer;<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:3'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(ii)<span style='mso-tab-count:1'> </span>The operator may leave the production casing in place, but must demonstrate that the casing exhibits mechanical integrity in a manner prescribed by the secretary. If the casing fails a mechanical integrity test, the secretary may require additional perforating and squeeze cementing or the placing of balanced cement plugs inside the casing. If it is determined that any formations identified in subsection 74:12:03:02(4)(a) were not sealed or separated when the production casing was cemented, the secretary may also require additional perforating and squeeze cementing. The secretary may also require the production casing to be perforated at the depth of the shoe of the surface casing and that cement be squeezed or circulated through the perforations; and<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><span style='mso-tab-count: 1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt; font-family:"Times New Roman"'>(iii)<span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>The operator may attempt to pull the production casing. After the retrievable part of the production casing has been removed, cement must be circulated to fill at least a 100-foot interval, of which at least 50 feet must be inside the casing stub. If reentry into the casing stub is not possible, the secretary shall determine the placement of the cement plug. The remainder of the hole must be plugged in the manner prescribed in subsection 74:12:03:02(4)(a);<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(c)&nbsp;&nbsp;Conversion of a well to a water well:<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:3'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>(i)<span style='mso-tab-count: 2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span>If a test hole may safely be used by the landowner as a potential freshwater well, the operator must follow the plugging procedures in this section to the base of the objective freshwater strata, if applicable. The surface owner must give a signed release to the operator before the conversion is made; and<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:2'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span><span style='mso-tab-count: 1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt; font-family:"Times New Roman"'>(ii)<span style='mso-tab-count:1'> </span>The well must then be constructed to meet specifications established in article 74:02.<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>Source:</b> 38 SDR 117, effective January 12, 2012.<o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>General Authority:</b> SDCL <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=45-9-11">45-9-11</A>, <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=45-9-13">45-9-13.</A><o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><span style='mso-tab-count:1'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span><b style='mso-bidi-font-weight:normal'>Law Implemented:</b> SDCL <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=45-9-11">45-9-11</A>, <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=45-9-15">45-9-15.</A><o:p></o:p></span></p> <p class=MsoNormal style='text-align:justify;tab-stops:.4in .6in .9in 1.1in 1.4in 1.6in 1.9in 2.1in 2.4in 2.6in 2.9in 3.1in 3.4in 3.6in 3.9in 4.1in'><span style='font-size:12.0pt;mso-bidi-font-size:10.0pt;font-family:"Times New Roman"'><o:p>&nbsp;</o:p></span></p> </div> </body> </html>