<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>span { white-space: pre-wrap; } p.s51a260d5-b08a-4c55-aa05-18531680e579P0 { margin-top: 0; line-height: 12.0pt; margin-bottom: 0; margin-left: 0; margin-right: 0; text-indent: 0.00in; text-align: justify; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; } span.s51a260d5-b08a-4c55-aa05-18531680e579C0 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s51a260d5-b08a-4c55-aa05-18531680e579C0-000000 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s51a260d5-b08a-4c55-aa05-18531680e579C0-000001 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s51a260d5-b08a-4c55-aa05-18531680e579000002 { color: black; background: white; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s51a260d5-b08a-4c55-aa05-18531680e579C0-000003 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s51a260d5-b08a-4c55-aa05-18531680e579C2 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; text-decoration: underline; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    </span><a href="https://sdlegislature.gov/Rules?Rule=44:75:13:23"><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000000">44:75:13:23</span></a><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000001">.  Ventilating systems.</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">A facility shall ensure its</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> ventilating systems maintain temperatures, minimum air changes of outdoor air </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">per</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> hour, minimum total air changes, and relative humidities as follows:</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    (1)  </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">For o</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">perating rooms</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">,</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">sixty-eight</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy-three</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> degrees Fahrenheit </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to 22.8 degrees centigrade, three outdoor, </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> total, and </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">sixty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> percent humidity;</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    (2)  </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">For d</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">elivery rooms</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">,</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">sixty-eight</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy-three</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> degrees Fahrenheit </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to 22.8 degrees centigrade, three outdoor, </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">fifteen</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> total, and </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">sixty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> percent humidity;</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    (3)  </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">For r</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">ecovery rooms</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">,</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> at least </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> degrees Fahrenheit </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">21.1 degrees centigrade, two outdoor, six total, and </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">sixty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> percent humidity;</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    (4)  </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">For n</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">ursery rooms</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">,</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> at least </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy-five</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> degrees Fahrenheit </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">23.9 degrees centigrade, two outdoor, six total, and </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">sixty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> percent humidity; and</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    (5)  </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">For i</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">ntensive care rooms</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">,</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy-five</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> degrees Fahrenheit </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">21.1 to 23.9 degrees centigrade, two outdoor, six total, and </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">twenty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> to </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">sixty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> percent humidity.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    For all other occupied areas, the facility shall maintain a minimum temperature of </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy-five</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> degrees Fahrenheit </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">23.9 degrees centigrade and at least </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">fifteen</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> percent humidity at winter design conditions with a minimum of at least two total air changes an hour. All air supply and air exhaust systems </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be mechanically operated. All fans serving exhaust systems </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be located at the discharge end of the system. Outdoor ventilation air intakes, other than for individual room units, </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be located as far away as practicable but not less than </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">twenty-five</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> feet </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">7.62 meters from plumbing vent stacks and the exhausts from any ventilating system or combustion equipment. The bottom of outdoor intakes serving central air systems </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be located as high as possible but not less than six feet </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">1.83 meters above the ground level or, if installed through the roof, three feet </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">0.91 meters above roof level. The mechanical ventilation systems </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be designed and balanced to provide make-up air and safe pressure relationships between adjacent areas to preclude the spread of infections and assure the health of the occupants. Room supply air inlets, recirculation, and exhaust air outlets </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be located with the grill or diffuser opening not less than three inches </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">0.08 meters above the floor. Corridors may not be used to supply air to or exhaust air from any room, except that exhaust air from corridors may be used to ventilate bathrooms, toilet rooms, or janitor's closets opening directly on corridors. Continuous mechanical exhaust ventilation </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be provided in all soiled areas, wet areas, and storage rooms. In unoccupied service areas, ventilation may be reduced or discontinued when the health and comfort of the occupants are not compromised.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    Laboratories </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be ventilated at a rate of six total air changes an hour. All ventilation air from the laboratory </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be directly exhausted to the outside. If this ventilation rate does not provide the air required to ventilate fume hoods and safety cabinets, additional air </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be provided. A filter with </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">ninety</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> percent efficiency </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be installed in the air supply system at its entrance to the media transfer room. Hoods in which highly radioactive materials are processed </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> have a face velocity of </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">one hundred fifty</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> feet </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">per</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> minute </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">0.76 meters </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">per</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> second, have a high-efficiency 99.97% filter, and each hood </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> have an independent exhaust system with the fan installed at the discharge point of the system. Hoods used for processing infectious materials </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> have a face velocity of </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">seventy-five</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> feet </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">per</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> minute </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">or </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">0.38 meters </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">per</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> second.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    Cooking appliances, other than microwave ovens, </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be provided with exhaust ventilation to the exterior of the building </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">that is able </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">to remove cooking odors, heat, and moisture.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    Each vehicle parking garage </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be provided with carbon monoxide detection to activate exhaust ventilation of six air changes each hour or to open the garage door if the area of the garage is under </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">one thousand</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> square feet. A sign </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be posted at the front of each parking space advising the driver to shut off the engine.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    Crawl spaces </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">must</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> be provided with mechanical ventilation at least one</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">-</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">half air changes each day or be provided with open perimeter venting as required by the International Building Code</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">, 2012 edition, section 1203</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000001">Source:</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> 42 SDR 51, effective October 13, 2015</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">; 50 SDR 62, effective November 27, 2023</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000001">General Authority:</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-12-13"><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000003">34-12-13</span></a><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">(1)(3)(4).</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000001">Law Implemented:</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-12-13"><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000003">34-12-13</span></a><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">    </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000001">Cross </span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0-000001">Reference: International Building Code</span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">, 2012 edition. Copies may be obtained from </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">the </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">International </span><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579C0">Code Council at </span><a href="https://shop.iccsafe.org/"><span class="s51a260d5-b08a-4c55-aa05-18531680e579C2">https://shop.iccsafe.org/</span></a><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">. Cost: $8</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">1</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">.</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">75</span><span class="s51a260d5-b08a-4c55-aa05-18531680e579C0">.</span></p><p dir="ltr" class="s51a260d5-b08a-4c55-aa05-18531680e579P0"><span xml:space="preserve" class="s51a260d5-b08a-4c55-aa05-18531680e579000002"> </span></p></div></body></html>