<html> <head> <title>Rule 44:75:14:17 Ventilation.</title> <META NAME="Keywords" Content="Administrative Rules 44:75:14:17"> <META NAME="Description" Content="Administrative Rules 44:75:14:17 Ventilation."> <meta http-equiv=Content-Type content="text/html; charset=windows-1252"> <meta name=Generator content="Microsoft Word 14 (filtered)"> <style> <!-- /* Font Definitions */ @font-face {font-family:Calibri; panose-1:2 15 5 2 2 2 4 3 2 4;} @font-face {font-family:Times; panose-1:2 2 6 3 5 4 5 2 3 4;} /* Style Definitions */ p.MsoNormal, li.MsoNormal, div.MsoNormal {margin:0in; margin-bottom:.0001pt; punctuation-wrap:simple; text-autospace:none; font-size:10.0pt; font-family:"Times","serif";} @page WordSection1 {size:8.5in 11.0in; margin:1.0in 1.0in 1.0in 1.0in;} div.WordSection1 {page:WordSection1;} --> </style> </head> <body lang=EN-US> <div class=WordSection1> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><a name="_GoBack"></a><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <b>44:75:14:17.&nbsp;&nbsp;Ventilation.</b> All air supply and air exhaust systems shall be mechanically operated. All fans serving exhaust systems shall be located at the discharge end of the system. All air supplied to an operating room, delivery room, nursery or any other sensitive area shall be delivered at or near the ceiling of the area served. All air exhausted from the area shall be removed near floor level. At least two exhaust outlets shall be used in each operating and delivery room. Exhaust wall outlets shall be located not less than three inches (0.076 meters) above the floor.</span></p> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;</span></p> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; A ventilation system in operating, delivery, emergency, isolation, central sterilization, or nursery room shall be a ducted system. A ventilation system using the building concealed space (return air plenum) from a clean room is not acceptable.</span></p> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;</span></p> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <b>Source:</b> SL 1975, ch 16, &#167; 1; 6 SDR 93, effective July 1, 1980; 14 SDR 81, effective December 10, 1987; 22 SDR 70, effective November 19, 1995; 29 SDR 81, effective December 11, 2002; transferred from &#167; 44:04:14:18, 42 SDR 51, effective October 13, 2015.</span></p> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <b>General Authority:</b> SDCL <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=34-12-13">34-12-13(1)</A>, (3), and (4).</span></p> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <b>Law Implemented:</b> SDCL <A HREF="/statutes/DisplayStatute.aspx?Type=Statute&Statute=34-12-13">34-12-13(1)</A>, (3), and (4).</span></p> <p class=MsoNormal style='text-align:justify;line-height:12.0pt'><span style='font-size:12.0pt;font-family:"Times New Roman","serif"'>&nbsp;</span></p> </div> </body> </html>