<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>span { white-space: pre-wrap; } p.sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0 { margin-top: 0; margin-bottom: 0; margin-left: 0; margin-right: 0; text-indent: 0.00in; text-align: justify; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; line-height: 108%; } span.sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000001 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000002 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003 { color: black; background: white; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:114"><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000">74</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000">:</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000">36</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000">:</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000">07</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000">:</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000000">114</span></a><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000001">.  Existing municipal solid waste landfill compliance with surface methane operational standards.</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> The owner or operator of an existing municipal solid waste landfill that meets the requirements of subdivision </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:111"><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000002">74:36:07:111</span></a><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(4) </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> comply with the following procedures for demonstrating compliance with the surface methane operational standards:</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(1)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">After installation and startup of the gas collection system, the owner or operator </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> monitor surface concentrations of methane along the entire perimeter of the collection area and along a pattern that traverses the landfill at no more than </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">thirty-</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">meter intervals or a site-specific established spacing for each collection area on a quarterly basis using an organic vapor analyzer, flame ionization detector, or other portable monitor meeting the specifications provided in §</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:115"><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000002">74:36:07:115</span></a><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">;</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(2)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">The background concentration </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">is</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> determined by moving the probe inlet upwind and downwind outside the boundary of the landfill at a distance of at least </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">thirty</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> meters from the perimeter wells;</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(3)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">Surface emission monitoring </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be performed in accordance with 40 C.F.R. Part 60, Appendix A, Method 21, section 8.3.1 (July 1, 20</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">24</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">) except the probe inlet </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be placed within </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">five</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> to </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">ten</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> centimeters of the ground. Monitoring </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be performed during typical meteorological conditions;</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(4)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">Any reading of </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">five hundred</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> parts per million or more above background at any location </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be recorded as a monitored exceedance. As long as the following actions are taken, the exceedance is not a violation of the operational requirements of subdivision </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:111"><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000002">74:36:07:111</span></a><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(4):</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">        </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(a)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">The location of each monitored exceedance </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">is</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> marked and the location and concentration </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">are </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">recorded. For location, the owner or operator shall determine the latitude and longitude coordinates using an instrument with an accuracy of at least four meters. The coordinates </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be in decimal degrees with at least five decimal places;</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">        </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(b)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">Cover maintenance or adjustments to the vacuum of the adjacent wells to increase the gas collection in the vicinity of each exceedance </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">are</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> made and the location </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">is</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> re-monitored within </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">ten</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> calendar days of detecting the exceedance;</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">        </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(c)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">If the re-monitoring of the location shows a second exceedance, additional corrective action </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be taken and the location </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be monitored again within </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">ten</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> days of the second exceedance. If the re-monitoring shows a third exceedance for the same location, the action specified in sub</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">section</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> (e) </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be taken, and no further monitoring of that location is required until the action specified in sub</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">section</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> (e) has been taken;</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">        </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(d)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">Any location that initially showed an exceedance but has a methane concentration less than </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">five hundred</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> parts per million methane above background at the </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">ten</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">-day re-monitoring specified in sub</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">section (4)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(b) or (c) </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be re-monitored </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">within </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">one month </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">after</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> the initial exceedance. If the </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">one</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">-month re-monitoring shows a concentration less than </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">five hundred</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> parts per million above background, no further monitoring of that location is required until the next quarterly monitoring period. If the </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">one</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">-month re-monitoring shows an exceedance, the actions specified in sub</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">section</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> (c) or (e) </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> be taken; and</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">        </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(e)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">For any location where monitored methane concentration equals or exceeds </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">five hundred</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> parts per million above background three times within a quarterly period, a new well or other collection device must be installed within </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">one hundred twenty</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> calendar days of the initial exceedance. An alternative remedy to the exceedance, such as upgrading the blower, header pipes or control device, and a corresponding timeline for installation may be submitted to the </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">s</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">ecretary for approval; and</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">(5)</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">  </span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">The owner or operator </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">must</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> implement a program to monitor for cover integrity and implement cover repairs</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">,</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> as necessary</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">,</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> on a monthly basis.</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000001">Source:</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> 46 SDR 64, effective November 25, 2019</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">; 52 SDR 27, effective September 17, 2025</span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">.</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000001">General Authority:</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-6"><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000002">34A-1-6</span></a><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">, </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-18"><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000002">34A-1-18</span></a><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">.</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">    </span><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000001">Law Implemented:</span><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-18"><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0-000002">34A-1-18</span></a><span class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76C0">.</span></p><p dir="ltr" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76P0"><span xml:space="preserve" class="sdce8118a-b832-48ab-a09b-9fa6c19cfa76000003"> </span></p></div></body></html>