<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>span { white-space: pre-wrap; } p.s18406b14-9c06-4564-9cbc-9df48c3b698eP0 { margin-top: 0; margin-bottom: 0; margin-left: 0; margin-right: 0; text-indent: 0.00in; text-align: justify; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; line-height: 108%; } span.s18406b14-9c06-4564-9cbc-9df48c3b698eC0 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000001 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.s18406b14-9c06-4564-9cbc-9df48c3b698e000003 { color: black; background: white; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:132"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000">74</span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000">:</span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000">36</span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000">:</span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000">07</span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000">:</span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000000">132</span></a><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000001">.  Recordkeeping for existing municipal solid waste landfill -- Control systems and exceedances.</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0"> Except as provided in subdivision </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:126"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">74:36:07:126</span></a><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(2), the owner or operator of a control system at an existing municipal solid waste landfill shall keep for five years, readily accessible continuous records of the equipment operating parameters specified to be monitored in §§ </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:117"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">74:36:07:117</span></a><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0"> through </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:124"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">74:36:07:124</span></a><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">, and records for periods of operation during which the parameter boundaries established during the most recent performance test are exceeded. The following records meet this requirement:</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(1)</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">  </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">The following constitute exceedances that must be recorded:</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">        </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(a)</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">  </span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">For enclosed combustors, except for boilers and process heaters with design heat input capacity of 44 megawatts, 150 million British thermal unit per hour, or greater, all 3-hour periods of operation during which the average temperature was more than 28 degrees Celsius or 82 degrees Fahrenheit below the average combustion temperature during the most recent performance test at which compliance with § </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:109"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">74:36:07:109</span></a><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0"> was determined; and</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">        </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(b)</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">  </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">For boilers or process heaters, whenever there is a change in the location at which the vent stream is introduced into the flame zone;</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(2)</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">  </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">The indication of flow to the control system and the indication of bypass flow or records of monthly inspections of car-seals or lock-and-key configurations used to seal bypass lines;</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(3)</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">  </span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">If a boiler or process heater with a design heat input capacity of 44 megawatts or greater is used to comply with § </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:109"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">74:36:07:109</span></a><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">, keep records of all periods of operation of the boiler or process heater;</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(4)</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">  </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">If using a non-enclosed flare, keep continuous records of the flame or flare pilot flame monitoring, and records of all periods of operation in which the flame or flare pilot flame is absent; and</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">(5)</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">  </span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">If complying with § </span><a href="https://sdlegislature.gov/Rules?Rule=74:36:07:98"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">74:36:07:98</span></a><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0"> using an active collection system, keep records of periods when the collection system or control device is not operating.</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000001">Source:</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0"> 46 SDR 64, effective November 25, 2019.</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000001">General Authority:</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-6"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">34A-1-6</span></a><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">.</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">    </span><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000001">Law Implemented:</span><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34A-1-18"><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0-000002">34A-1-18</span></a><span class="s18406b14-9c06-4564-9cbc-9df48c3b698eC0">.</span></p><p dir="ltr" class="s18406b14-9c06-4564-9cbc-9df48c3b698eP0"><span xml:space="preserve" class="s18406b14-9c06-4564-9cbc-9df48c3b698e000003"> </span></p></div></body></html>