<html xmlns="http://www.w3.org/1999/xhtml"><head><meta charset="UTF-8" /><title></title><meta name="Generator" content="PowerTools for Open XML" /><style>p.sc451b637-c77d-4cef-8ebf-fa85a7311e08P0 { margin-top: 0; margin-bottom: 0; margin-left: 0; margin-right: 0; text-indent: 0.00in; text-align: justify; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; line-height: 108%; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08C0 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000000 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000001 { color: black; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: bold; margin: 0; padding: 0; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08000002 { color: black; background: white; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000003 { color: #0000FF; background: white; font-family: 'Times New Roman', 'serif'; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000004 { color: black; background: white; font-family: Times; font-size: 12pt; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000005 { color: black; background: white; font-family: Times; font-size: 12pt; text-decoration: underline; font-style: normal; font-weight: normal; margin: 0; padding: 0; } span.sc451b637-c77d-4cef-8ebf-fa85a7311e08C2 { color: #0000FF; background: white; font-family: Times; font-size: 12pt; text-decoration: underline; font-style: normal; font-weight: normal; margin: 0; padding: 0; } </style></head><body><div><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    </span><a href="https://sdlegislature.gov/Rules?Rule=44:73:12:27"><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000000">44:73:12:27</span></a><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000001">.  Ventilating systems.</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> The </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">facility's </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">ventilating systems</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> must meet the following requirements</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">:</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    (1)  All occupied areas of the building </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> maintain a minimum humidity level of </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">fifteen percent</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> relative humidity provided through the building central ventilation system;</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    (2)  Beauty shops </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> provide a minimum of </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">fifteen</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> air changes per hour of exhaust ventilation when the room is in use;</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> and</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    (3)  Toilet and bathing rooms </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> provide a minimum of </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">ten</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> air changes per hour of exhaust ventilation.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    For occupied areas, the facility shall maintain a minimum temperature of </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">seventy-five</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> degrees Fahrenheit</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">or </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">23.9 degrees centigrade</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> and at least </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">fifteen</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> percent humidity </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">during</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> winter conditions with a minimum of at least two total air changes </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">per</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> hour. All air supply and air exhaust systems </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be mechanically operated. All fans serving exhaust systems </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be located at the discharge end of the system. Outdoor ventilation air intakes, other than for individual room units, </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be located as far away as practicable but not less than </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">twenty-five</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> feet</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">or </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">7.62 meters</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> from plumbing vent stacks and the exhausts from any ventilating system or combustion equipment. The bottom of outdoor intakes serving central air systems </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be located as high as possible but not less than six feet</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">or </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">1.83 meters</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> above the ground level or, if installed through the roof, three feet</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">or </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">.91 meters</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> above roof level. Each mechanical ventilation system </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be designed and balanced to provide make-up air and safe pressure relationships between adjacent areas to preclude the spread of infections and assure the health of the occupants. Each room supply air inlet, </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">air </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">recirculation, and exhaust air outlet </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be located with the grill or diffuser opening not less than three inches</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">or </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">.08 meters</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">,</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> above the floor. A corridor may not be used to supply air to or exhaust air from any room, except that exhaust air from corridors may be used to ventilate bathrooms, toilet rooms, or janitor's closets opening directly on corridors. Continuous mechanical exhaust ventilation </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be provided in all soiled areas, wet areas, and storage rooms. In unoccupied service areas, ventilation may be reduced or discontinued when the health and comfort of the occupants are not compromised.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    Each cooking appliance, other than </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">a </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">microwave ove</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">n</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">, </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be provided with exhaust ventilation to the exterior of the building </span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">that is able </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">to remove cooking odors, heat, and moisture.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    Each vehicle parking garage </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be provided with carbon monoxide detection to activate exhaust ventilation of six air changes each hour or to open the garage door if the area of the garage is under </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">one thousand</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> square feet. A sign </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be posted at the front of each parking space advising the driver to shut off the engine.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    Each crawl space </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">must</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> be provided with mechanical ventilation at least one</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">-</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">half air changes each day or be provided with open perimeter venting as required by the International Building Code</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">, 2012 edition, section 1203</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000001">Source:</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> SL 1975, ch 16, § 1; 4 SDR 14, effective September 14, 1977; 6 SDR 93, effective July 1, 1980; 14 SDR 81, effective December 10, 1987; 22 SDR 70, effective November 19, 1995; 26 SDR 96, effective January 23, 2000; 29 SDR 81, effective December 11, 2002; 30 SDR 84, effective December 4, 2003; 32 SDR 128, effective January 30, 2006; transferred from § </span><a href="https://sdlegislature.gov/Rules?Rule=44:04:13:26"><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000003">44:04:13:26</span></a><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">, 42 SDR 51, effective October 13, 2015</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">; 51 SDR 53, effective November 11, 2024</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000001">General Authority:</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-12-13"><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000003">34-12-13</span></a><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000001">Law Implemented:</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> SDCL </span><a href="https://sdlegislature.gov/Statutes?Statute=34-12-13"><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000003">34-12-13</span></a><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">    </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000001">Reference:</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0"> </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000001">International Building Code</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0">, 2012 edition. </span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000004">Copies may be obtained from the International Code Council at</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000005"> </span><a href="https://shop.iccsafe.org/"><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C2">https://shop.iccsafe.org/</span></a><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000004">. Cost:</span><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000004"> $132.00</span><span style="white-space: pre-wrap;" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08C0-000004">.</span></p><p dir="ltr" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08P0"><span style="white-space: pre-wrap;" xml:space="preserve" class="sc451b637-c77d-4cef-8ebf-fa85a7311e08000002"> </span></p></div></body></html>